TANK PROTOCOL
INDIA PETROCHEMICAL EMISSION STANDARDS
🏠 Home 👤 Profile
India Petrochemical Emission Standards
Chimney/stack, process, fugitive, storage, and loading emission limits for petrochemical (basic and intermediates) plants
◉ ENVIRONMENT (PROTECTION) FOURTH AMENDMENT RULES, 2012 (GSR 820(E)) STYLE CHECK · NOT A REGULATORY SUBMISSION TOOL
⚠ Indicative tool only. Source: Gazette of India Extraordinary, Ministry of Environment and Forests notification G.S.R. 820(E), dated 9 November 2012, "Environment (Protection) Fourth Amendment Rules, 2012" — amending Schedule I Serial No. 38 (Petrochemical, Basic and Intermediates) and Schedule VI of the Environment (Protection) Rules, 1986. Published bilingually (Hindi then English); all figures below are transcribed from the notification's own English text, cross-checked against an independent Hindi-to-English translation of the same sections — every value matched exactly. Verify against the current, consolidated Rules (this is a single 2012 amendment; later amendments may exist) before using this for compliance purposes.
Identification
Research entries stay private to you for practice/testing. Switch to Official once this is a real design your company should see.
B. Chimney/Stack Emissions (Furnace/Boiler/Heater/Vaporiser)
All values corrected to 3% oxygen. Wet scrubber must operate during decoking. CO norms apply only to Phthalic Anhydride (PA), Maleic Anhydride (MA), Terephthalic Acid (PTA), and Dimethyl Terephthalate (DMT) plants — not applicable to standalone existing PA/MA plants under 30,000 MT/year with a chimney/stack ≥30m tall.
Result Not evaluated
Limit—
Process Emission — Specific Pollutant
HAP = Hazardous Air Pollutant: pollutants causing cancer or other serious health effects, or adverse environmental/ecological effects.
Result Not evaluated
Limit—
Process Emission — General Pollutant
General pollutant limits do not distinguish existing vs. new plants (single limit applies to both).
Result Not evaluated
Limit—
Schedule VI, Part D, Serial 9 — New/Expansion Plant Quantum Limits
Load/mass-based standard, applies to new or expansion petrochemical (basic and intermediates) plants specifically — a different basis than the concentration-based process emission limits above.
Result Not evaluated
Limit—
Loading Emission Control (Road Tank/Truck/Rail Tank/Wagon)
Compliance may be demonstrated by EITHER the VOC reduction percentage OR the direct emission limit — meeting either criterion is sufficient.
Result
VOC reduction requirement—
Emission requirement—
Compliant via—
D. Storage of Benzene, VCM and ACN
Reference — one of three technology options shall be provided:
(i) Fixed roof tank (FRT) with vapour incineration, ≥99.9% VOC removal efficiency; or
(ii) IFRT/EFRT with double seals, emission-reducing roof fitting, fitted with fixed roof, ≥99% vapour removal efficiency; or
(iii) Internal floating roof with nitrogen blanketing between the fixed and floating roofs.

For general petrochemical/petroleum product storage (not specifically benzene/VCM/ACN), roof type by tank capacity and total vapour pressure, plus seal gap limits, are already covered in the Rim Seal Gap Survey tool's India profile (same source notification, Section C).
Save & Report