Minimum nozzle body thickness and reinforcement design for shell mountings O/D 80mm and above (BS EN 14015:2004, §13.1)
◉ BS EN 14015:2004 §13.1 STYLE CHECK · NOT A REGULATORY SUBMISSION TOOL
⚠ Indicative tool only, and distinct from the existing API 650-based Nozzle Reinforcement calculator. EN 14015's area-replacement formula (0.75×d×e1) is structurally different from API 650's approach — verified directly against this edition's page images. Table 19 applies to set-on nozzles O/D 80mm and above only; smaller nozzles and set-through/set-in details follow different clauses not covered here.
Identification
Research entries stay private to you for practice/testing. Switch to Official once this is a real design your company should see.
Minimum Nozzle Body Thickness (Table 19, §13.1.2)
Applies to O/D 80mm and above (§13.1.1). Manholes used as nozzles require ≥600mm minimum internal diameter unless otherwise agreed.
Result
Minimum shell nozzle body thickness en
Required Reinforcement Area — Area Replacement Method (§13.1.4)
Areq = 0.75 × d × e1. Reinforcement (thickened insert plate or circular reinforcing plate) shall have effective diameter 1.5d < dr < 2d.
Result Not evaluated
Required reinforcement area Areq
Permitted dr range (1.5d to 2d)
dr provided vs. range
Alternative — Thickened Nozzle Body Method (§13.1.5)
L ≥ 1.17√(rmen), where rm = (ro+ri)/2. The thickened nozzle body protrudes both sides of the shell plate (see Fig. 13). Nozzle thickness shall be such that the stress concentration factor Scf does not exceed 2 (Fig. 14, not computed here).
Result
Mean radius rm
Minimum reinforcement length L
Nozzle Wall Credit Factor & Post-Weld-Heat-Treatment Spacing (§13.1)
Replacement factor y (credits the nozzle wall's own excess thickness toward reinforcement) uses rm and en from the card above. Subsequent welds to a post-weld-heat-treated nozzle body shall not be closer than 2.5√(rien).
Result
Replacement factor y
Minimum spacing to subsequent welds (after PWHT)
Save & Report