Design of a flat-bottom tank for uniform external pressure (vacuum) to API 650 Annex V: the roof under the total roof pressure, the roof-to-shell region, the shell by the transformed-shell method for wind plus external pressure and for external pressure alone, the number, spacing and size of intermediate stiffeners, the top and bottom end stiffeners, their attachment welds and the bottom under external pressure and flooding
New here? Read the User Manual — the two shell conditions, the transformed shell, placing stiffeners, worked examples and how to read the results.
◉ API 650 14TH ED. (AUGUST 2025) ANNEX V · V.7 ROOF · V.8 SHELL · V.9 BOTTOM · NOT A REGULATORY SUBMISSION TOOL
⚠ Indicative tool only. Follows API 650, 14th edition (August 2025), Annex V, for design external pressures over 0.25 kPa (1 in. of water) and up to 6.9 kPa (1 lbf/in²), checked against that text and its V.10 example. The units also choose the rule set: SI and US customary each use the printed equations of that system. Annex V does not apply to aluminum tanks. Supported cone roof plates (V.7.1) are designed by agreement and are a record item here.
Unsaved inputs were found on this device.
Identification
Switching converts what is typed in and the rule set (the printed SI or US customary equations). Saved records stay in SI.
Summary of checks
Enter the tank, its shell courses and the design external pressure.
1. Tank and Shell
Shell courses from the bottom (course 1) up. Annex V numbers them from the top; the tool does that for you.
2. Loads (V.3, 5.2.2)
3. Fixed Roof (V.7)
4. Shell Buckling (V.8.1)
5. Stiffeners (V.8.2)
Sections are on the outside of the shell. An angle has its horizontal leg against the shell and its vertical leg at the outer end. Or enter the section’s area, its own moment of inertia and its centroid from the shell mid-plane.
6. Bottom (V.9)
7. Design Record (Annex V)
Tick each item once it is confirmed. Items that don’t apply are hidden.
Save & Report
Inputs are kept on this device as you type and offered back if the page is closed before saving.