About this tool
The Cathodic Protection calculator follows API RP 651 for the soil side of aboveground storage tank bottoms: whether protection is needed, the pad and soil, liners and replacement bottoms, the design current, rectifier and anodes, the permanent reference electrodes, a potential survey judged against the three protection criteria, and the survey and maintenance dates.
It follows the 4th edition (September 2014), the text on file. A 5th edition was issued in August 2024 and has not been compared yet. API RP 651 is a recommended practice: its criteria are minimum indicators, and others may be used where corrosion control can be shown (8.2.2). Design and testing are for a qualified corrosion specialist.
Quick start
Two samples: a new 36 m tank on a sand pad over a liner with an impressed-current design, and an existing 24 m tank with an annual survey that has one unprotected reading, overdue checks and pad chemistry worth a look.
- 1Section 1: D, new or existing, temperature, the pad, any liner or second bottom, internal lining.
- 2Section 2: pad and soil resistivity, pH, chlorides, sulfates, sulfides; owner limits if set.
- 3Section 3: impressed current or galvanic, the current density (or a test current), rectifier margin, anode output and resistance.
- 4Section 4: the reference electrode and the readings: native, on and instant-off at each point, perimeter or under the tank.
- 5Section 5: dates of energizing, the last rectifier check and the last annual survey.
Pad and soil (Table 1, 5.3)
| Resistivity, Ω·cm (Table 1) | Potential corrosion activity |
|---|---|
| under 500 | very corrosive |
| 500 to 1000 | corrosive |
| 1000 to 2000 | moderately corrosive |
| 2000 to 10,000 | mildly corrosive |
| over 10,000 | progressively less corrosive |
- Resistivity alone should not judge corrosivity (5.3.1.2); the tool reads it with the chemistry.
- pH (5.3.2.1 g): corrosion fairly independent of pH from 5.0 to 8.0, appreciably higher below 5.0, lower above 8.0.
- Chlorides (h): pitting can begin at 10 ppm, and chlorides raise the current needed. Sulfates (i) over 200 ppm often mean organic matter. Sulfides (j) over 0.10 ppm may mean sulfate-reducing bacteria.
- There is no consensus limit for chlorides, sulfates or sulfides: the owner specifies them. Without owner limits the tool shows the RP indicators as Notes; with them, a value over the limit fails.
- Concrete and asphalt pads can block the current while water under the bottom still corrodes it (5.3.3, 5.3.6); a liner under the tank means the anodes must be between the liner and the bottom (5.4.3, 7.2.3, Figure 7); a new bottom over an old one needs the CP in the space between them (7.2.4, Figure 8).
Design current, rectifier and anodes (7.3.5)
| Step | Rule | Design sample |
|---|---|---|
| Bottom area | πD²/4 | 36 m → 1,017.9 m² |
| Current density (7.3.5.2.2.1) | without a test: 1 – 2 mA/ft² ambient, 0.5 mA/ft² close-coupled anodes, 2 – 8 mA/ft² elevated temperature; blank uses the top of the range | 2 mA/ft² = 21.53 mA/m² |
| Current | I = A × i, or the current found by a current requirement test (Figure 9) | 1,017.9 × 21.53 / 1000 = 21.91 A |
| Rectifier (7.3.5.2.3 c) | excess capacity typically 10 to 50 % | +25 % → 27.39 A |
| Anodes (7.3.5.2.1.4) | total current ÷ rated output per anode, plus more for distribution and failures | 21.91 ÷ 4 A → 6 anodes |
| Anode resistance | Dwight, one vertical anode: R = ρ/(2πL)·(ln(8L/d) − 1), ρ in Ω·m — cited by the RP (7.3.5.2.2.3 c) but not printed | 30 Ω·m, 2.1 m, 0.25 m → 7.293 Ω |
| Voltage (7.3.5.2.2.3) | E = I × R | 7.293/6 + 0.5 = 1.716 Ω; 27.39 A × 1.716 = 47.0 V |
- Dividing one anode’s resistance by the number of anodes ignores their mutual interference: it understates the bed resistance. Use a measured value where you can.
- Galvanic anodes drive only about 0.25 V (zinc) to 0.75 – 0.9 V (magnesium) against protected steel (Table 2): the tool fails a galvanic design whose E = I × R exceeds 0.9 V.
- Permanent reference electrodes (Table 4): 3 for 6 – 12 m, 4 for 12 – 18 m, 5 for 18 – 30 m, 6 for 30 – 45 m, 7 for 45 – 76 m, 10 for 76 – 107 m, equally spaced across the diameter.
The protection criteria (8.2.2) and the survey
| Criterion | Meets when | Example (mV CSE) |
|---|---|---|
| 8.2.2.1 — current applied | on-potential at least −850 mV, with voltage drops other than at the bottom considered | on −880, no instant-off: on only (a Note: consider the IR drop) |
| 8.2.2.2 — polarized | instant-off at least −850 mV | off −920: protected |
| 8.2.2.3 — polarization | at least 100 mV between native (or depolarized) and instant-off | native −575, off −790: shift 215 mV, protected |
| None | none of the above | native −550, on −930, off −620: shift 70 mV, not protected |
- Once an instant-off value is measured it is the IR-free potential, so a reading whose on-potential passes but whose instant-off misses both −850 mV and 100 mV is not protected.
- −850 mV polarized may be impractical on a bare bottom (8.2.2.2); use the 100 mV criterion with native or depolarized values.
- Other electrodes (Table 3): −850 mV CSE equals −780 mV saturated calomel, −800 mV silver/silver chloride, +250 mV zinc. Readings are converted to CSE before judging.
- Perimeter readings may not represent the centre of the bottom (8.3.1): without an under-tank reading the tool adds a Note. Potentials also vary with the liquid level (8.3.5).
Surveys, checks and records (11.3, 11.4)
| Item | Interval |
|---|---|
| Impressed current sources | checked at intervals not exceeding two months (11.3.2.2) |
| CP survey; impressed current facilities inspected | annually (11.3.1.2, 11.3.2.3) |
| After energizing | right away, and again after polarization has stabilised (may take several months) (11.3.1.1) |
| Records of CP effectiveness | five years unless regulation allows less; records of need kept while the tank is in service (11.4.7) |
The tool gives the next due dates from the last dates entered and fails a check that is overdue on the assessment date.
The checks
| Check | Clause | Result |
|---|---|---|
| Barrier and access to the bottom | 5.4.3, 7.2 | a Note with a liner or second bottom |
| Pad resistivity, pH | Table 1, 5.3.2.1 g | a Note when corrosive or below pH 5; fails under an owner minimum |
| Chlorides, sulfates, sulfides | 5.3.2.1 h – j | a Note above the RP indicators; fails over owner limits |
| Number of anodes | 7.3.5.2.1.4 | fails when fewer than the current needs |
| Galvanic driving voltage | Table 2, 6.2.3 | fails over 0.9 V |
| Protection criteria | 8.2.2, Table 3 | fails if any reading meets no criterion; a Note for on-only readings |
| Readings under the tank | 8.3.1, 9.4.4 | a Note with perimeter readings only |
| Rectifier check, annual survey | 11.3 | fails when overdue |
| Installation and records checklist | 7.3.6, 9, 11.4 | a Note until every item is ticked |
How the numbers were checked
- Tables 1 – 4, the criteria of 8.2.2, the current densities of 7.3.5.2.2.1 and the intervals of 11.3 were read from the 4th edition text.
- The design sample is recomputed in this manual’s build; the test suite (26 checks) covers Table 3 conversions, Table 1 and Table 4 bands, Dwight’s equation, each criterion, owner limits, due dates in two time zones, save, reopen and the report.
Saving, reopening and reports
- Inputs, including the survey readings, are kept on this device as you type. Calculate & Save stores the check in the
cathodicProtectionCalcscollection; Show saved checks lists them for the tank. - Print / PDF report: summary, need, pad, design, the survey table and chart, due dates and the checklist.
- Effective cathodic protection is one of the API 653 Table 6.1 credits in the Inspection Interval tool.
Limits and interpretations
- Built on the 2014 edition; the 2024 edition has not been compared.
- Internal (product-side) cathodic protection (7.4) and interference testing (Section 10) are not calculated.
- The anode-bed resistance from Dwight ÷ n is a lower bound.
- No over-protection limit is given by the RP; follow the coating or lining manufacturer where one applies.
Glossary
| CSE | Saturated copper/copper sulfate reference electrode. |
| Instant-off | The potential read just after interrupting the protective current: the polarized potential without the IR drop. |
| Native / depolarized | The potential before current is applied, or after it has been off long enough to decay. |
| IR drop | The voltage drop in the soil between the reference electrode and the bottom while current flows. |